Shop Heater Circuits and Garage Sub Panels in Alberta

Buying the heater is the easy part. Feeding it is the job.

I’m Dustin Krzywy, Master Electrician #7172, out of Ponoka. Every fall the same call comes in. A guy bought an electric shop heater, hung it, and now wants to know why he cannot just plug it in. Fair question, so here is the honest answer.

TL;DR: A 240V electric shop heater needs a dedicated circuit sized off the heater’s own nameplate, wire sized for that circuit and the run length, and in most cases a disconnect you can see from the heater. Most garages and shops do not have spare capacity for that, which is why the real job is usually a sub panel and a proper feed. It needs a permit and an inspection. Call me at 403-340-9213 and I will tell you which one you are looking at.

Start at the Nameplate, Not the Breaker Aisle

Every electric heater has a plate on it with its voltage and its load. That plate is the start of the whole conversation. Not what the guy at the store said, not what your buddy’s heater takes.

What that plate tells me:

  • The voltage it is built for. A heater built for 240V will not run on a 120V circuit, and one built for three phase will not run on single phase at all. On farms and in bigger shops this catches people out more than you would think.
  • The load it draws. That is what sizes the breaker and the wire.
  • Whether it is a continuous load. Heating equipment that runs for hours at a stretch is treated differently from something that cycles on for a minute. The Canadian Electrical Code accounts for that, and it means the circuit gets sized above the heater’s running load rather than right at it.

So the first thing I ask on the phone is always: read me the plate. Half the time that one answer changes the whole quote.

The Circuit: Dedicated, Sized Right, Wired Right

Three parts to it.

It gets its own circuit. A shop heater sharing a circuit with the lights, the compressor or the welder plug is going to trip, and it will trip when everything is running, which is January.

The breaker is sized from the nameplate, with continuous load allowed for. Not sized to whatever spare breaker is in the panel. I have pulled out heaters running on a breaker somebody picked because it fit the empty slot.

The wire is sized for the breaker and for the run. This is the part that gets missed on shops. A detached shop out in the yard is a long run, and a long run of undersized wire means voltage drop. The heater underperforms, runs longer, and the wire runs warmer than it should. The wire also has to suit where it goes: buried, in conduit, through an unheated space, exposed in a shop where things get bumped.

Most permanent heaters get hard wired, not plugged in. And the Canadian Electrical Code generally wants a means of disconnecting the heater that you can see from where you are working on it, so nobody flips it back on while your hands are in it. On a shop heater hung up in a corner, that disconnect is not a nice-to-have.

Why the Answer Is Usually a Sub Panel

Here is the pattern I see in almost every shop and garage in central Alberta.

The building was wired years ago for lights and a couple of plugs, fed off a small breaker in the house panel. Since then it picked up a compressor, a welder plug, a fridge, a work bench full of tools, maybe an EV charger, and now a heater.

Each addition was reasonable. Together they are more than the feed was ever sized to carry.

A sub panel in the shop fixes the actual problem instead of squeezing one more circuit out of a feed that is already maxed. What it gets you:

  • Real capacity for the heater, the welder plug, the compressor and whatever comes next
  • Breakers out in the shop instead of a walk to the house every time something trips
  • A proper feed sized once, so the next addition is a breaker and not a rebuild
  • Room for the things you have not thought of yet, which on every shop I have ever wired is at least two things

The feed to a detached shop is the piece that decides everything. If it is a small underground run from the house, that run is your ceiling no matter what panel you hang inside. Sorting the feed and the panel together is the job worth doing once.

Detached Shop, Attached Garage: Not the Same Job

An attached garage is usually a shorter run and simpler work.

A detached shop is a different animal. There is a feed to get out there, usually underground, and that means trenching, depth, mechanical protection and doing it before the ground freezes. It also means the shop needs its own grounding done correctly, which is a detail that gets skipped by people who should know better.

If your shop feed needs replacing, fall is the window. Once the frost is in, trenching gets expensive fast, and the job that was straightforward in September turns into a bad day in December.

Permits, Inspection, and Why It Matters on a Shop

Adding a circuit, adding a sub panel, or running a new feed to a building is permitted work in Alberta under the Safety Codes Act. A licensed contractor pulls the permit and the work gets inspected.

It matters more than people think on a shop:

  • Insurance. A shop fire that traces back to unpermitted wiring on a heater is a bad conversation to have with an adjuster.
  • Resale. An acreage with a shop full of unpermitted wiring is a sticking point at sale.
  • The heater itself. Manufacturers have installation requirements around clearances and mounting. Ignore those and you have a warranty problem on top of a code problem.

When I do this work, I pull the permit and book the inspections. That part is not your job.

What It Looks Like When I Come Out

I read the heater plate. I open the panel in the house or the shop and see what is actually in there, not what the labels claim. I look at the feed to the building. I measure the run. Then I tell you honestly whether you are looking at one circuit or a sub panel and a feed, and you get a written quote for it.

Some guys want the whole thing done properly now. Some want the heater going this winter and the panel next year. Both are fine as long as you know which one you bought.

If you want a look before it gets cold, a quote is free. For more on panel and service work, see my panel upgrade services.

FAQ

What size breaker does a 240V shop heater need?

It comes off the heater’s nameplate, not off a rule of thumb. The plate gives the voltage and the load, and because a shop heater runs for long stretches it is treated as a continuous load, so the circuit gets sized above the running load per the Canadian Electrical Code. Read me the plate and I can tell you in a minute.

Can I plug my electric shop heater into a regular outlet?

Not a 240V one, no. A regular outlet in a shop is 120V on a general purpose circuit, and a 240V heater needs its own dedicated 240V circuit with the right wire and breaker. Most permanent shop heaters are hard wired rather than plugged in, with a disconnect you can see from the heater.

Do I need a sub panel in my garage or shop?

If the building is already carrying lights, plugs, a compressor and a welder plug, and now you are adding a heater, usually yes. A sub panel plus a properly sized feed gives you real capacity instead of squeezing another circuit out of a feed that is already at its limit. It also puts the breakers where you are working.

Do I need a permit to wire a heater in my shop in Alberta?

Yes. Adding a circuit, adding a sub panel or running a new feed to a building is permitted work under Alberta’s Safety Codes Act, and it gets inspected. A licensed electrical contractor pulls the permit under their licence and books the inspections. It also matters for insurance and at resale.


Got a heater sitting in the box, or a shop panel with nothing left in it? Let me look at what you have got and give you a straight, free quote.

Call East Country Electric at 403-340-9213. Master Electrician #7172, serving Ponoka, Lacombe, Stettler, Camrose, Wetaskiwin, Red Deer, the rest of central Alberta and into Saskatchewan. More about what I do here.